Water Cooling Module

The Water Cooling Module (ccpe:water_cooling_module) is the Engine System's liquid cooling module: it carries an 8000 mB coolant tank and adds a fixed dissipation component (K_WATER) to the engine's Newton cooling.
The key difference from the Cooling Air Duct: water cooling takes small shares of both ram air and ambient pressure (25% each) — a liquid loop does not care about the air itself. So it is the answer for the three situations where ducts are weakest: static, low speed and high altitude. The price is coolant consumption, which accelerates while the engine runs hot, and it is also heavy.
On top of that it draws on the engine's output: every working module permanently ties up 512 SU of stress — with no shaft connection required (the engine core reports the draw as its own network stress, see "Stress cost" below). Water cooling is not free dissipation; you pay stress for cooling.
Coolant
| Item | Rule |
|---|---|
| Capacity | 8000 mB, single tank (one coolant type at a time; drain it before switching) |
| Filling | Fluid pipes/pumps (the block exposes the FluidHandler capability), or right-click with a fluid container (right-click = item → tank first; sneak-right-click = tank → item first) |
| Coolants only | Only fluids listed in the datapack coolant/*.json table are accepted. Anything else (lava, crude oil, …) cannot be inserted, and the held container is not consumed |
| Removal | The coolant inside is lost when the module is broken (no bucket refund) |
Why only coolants
The coolant table doubles as a whitelist: whatever goes in is guaranteed to have a cooling coefficient, and the engine's source scan skips water cooling modules so their contents are never mistaken for boiler water or fuel.
Cooling contribution
k_water = K_WATER × Σ_modules [ min(amount / 4000, 1) × coolant efficiency ] × loop opening × waterRam × waterPressure
K_WATER = 0.37 (per module at full effect)
waterRam = 1 + max(0, ram(speed) − 1) × 0.25 <- only 25% of the ram **bonus** (×1.25 at full ram; no penalty at rest)
waterPressure = 1 − (1 − f(pressure)) × 0.25 <- only 25% of the pressure loss (f 0.54 → ×0.885)
- Added outside the brackets:
K_total = (K_CORE×length + K_AMB×running chambers)×f(pressure) + K_DUCT×ducts×shutter×ram×f(pressure) + k_water×waterRam×waterPressure— water cooling takes small shares of both ram air and pressure (25% each), so it loses far less dissipation at altitude than ducts do. Full model on the Temperature & Cooling page. - Amount curve: full effect at ≥ 4000 mB; linear falloff below 4000 mB; 0 at 0 mB (smooth, no flicker at the threshold).
- Coolant efficiency: datapack field
efficiency(water = 1.0,aeronautics:levitite_blend= 1.5), multiplied directly into the dissipation. - Loop opening: Lua
setWaterCooling(0..1)(default 1.0 = fully open); 0 = loop closed (neither cools nor evaporates). - Stacking:
k_wateris the sum over all working modules.
Boiling also removes heat (latent heat of evaporation)
Once the coolant boils above 200°C, what escapes really is heat (1 mB of water ≈ 2.26 kJ vaporised) — so boiling drains the tank and cools the engine:
heat_net = heat − EVAP_LATENT_GAIN × 20 × Σ(boiling mB/tick)
EVAP_LATENT_GAIN = BOIL_COOLING_PER_DEGREE ÷ COOLANT_BOIL_MB_PER_DEGREE_SEC = 1.5 ÷ 5.0 = 0.3 °C/s per mB/s
(equivalent form: Q_evap = 1.5 × (T − 200), i.e. "1.5 °C/s removed per °C of superheat" — same dimension as k_total)
- This term does not go into
k_water: it is a mass-flow term (∝ drain rate), independent of the temperature difference, so it ignores ram air and pressure as well. - It is exactly 0 at T ≤ 200°C → every existing equilibrium below 200°C (ducts, water-cooling dissipation, economy band, cold penalty) is unchanged.
- You only get the cooling if you really burn coolant: the evaporation rate and the drain rate are the same number, so it can never "cool more while burning less".
- Steam engines / closed loop → 0 (those configurations do not drain coolant either).
Calibration baseline (fuel heat=1.0, 4 full-load fluid chambers + 1 full water module, 1 core segment, static, sea level → heat=120, k_total≈0.54):
| Equilibrium | Boiling drain | Runtime per 8000 mB | |
|---|---|---|---|
| Without the boiling term | ≈238°C (repeated 220 hard-stop / 200 restart cycle) | 0 | — |
| With it (current value) | ≈210°C (stable) | ≈51.1 mB/s | ≈2.6 minutes |
Plateau temperature and runtime are two separate constants
BOIL_COOLING_PER_DEGREE = 1.5(°C/s per °C of superheat) locks the plateau:T − 200 = (heat − 180×k_total) / (that value + k_total).COOLANT_BOIL_MB_PER_DEGREE_SEC = 5.0sets only how fast the tank empties: a full tank lasts ≈2.6 minutes.EVAP_LATENT_GAIN= the ratio = 0.3, i.e. only ≈17% of the pure latent-heat equivalent (≈1.74) is credited — the rest leaves through the vent/exhaust. That is the price of the shorter runtime.- Design ruling: boiling-driven high-temperature operation is an emergency measure, never a long-term mode. Adjust the drain rate to change the runtime; the plateau will not drift.
- Hotter fuels (diesel,
heat=1.25) still push the plateau to ≈225°C and overheat — add another water module or run rich in that case.
Where K_WATER = 0.37 comes from: "one full module holds two full-load fluid chambers at ~150°C"
Q = 2 chambers × full load(1.0) × fuel heat(1.0) × BASE_HEAT_FLUID(30) = 60 °C/s
need k = Q / (150 − 20) ≈ 0.462
k_air = K_CORE×length + K_AMB×2 ≈ 0.09 (1 core segment) ~ 0.10 (2 core segments)
K_WATER = 0.462 − 0.10 ≈ 0.36 → shipped as 0.37
Equilibrium temperatures at sea level, static, 2 chambers, fuel heat = 1.0, no ducts, 2 core segments (k_air = 0.01×2 + 0.04×2 = 0.10) — T_eq = 20 + Q/k with Q = 2 × 30 × load (temperature is clamped at 264°C):
| Coolant | k_water | Full load 100% | 63% | 43% | 20% (idle) |
|---|---|---|---|---|---|
| No module / no coolant | 0 | clamped 264 (overheat) | clamped 264 (overheat) | clamped 264 (overheat) | ≈140°C |
| 2000 mB water (50% fill) | 0.185 | ≈231°C (overheat) | ≈153°C | ≈111°C | ≈62°C |
| 4000 mB+ water (full effect) | 0.37 | ≈148°C ✅ | ≈100°C | ≈75°C | ≈46°C |
| 8000 mB levitite (×1.5) | 0.555 | ≈112°C | ≈78°C | ≈59°C | ≈38°C |
(On a 1-segment engine k_air = 0.09, and a full water module at full load lands at ≈ 150°C — so "two chambers at ~150°C" holds for both 1- and 2-segment cores. Note: the 2026-09 retune moved K_WATER 0.33→0.37 and passive k_air 0.14→0.10; they still add up to 0.47, so the "≈148°C" result is unchanged.)
Water cooling is strong: low load overcools
An engine with a big water-cooling module drops below 100°C at low load, which triggers the overcooling fuel penalty. Either raise the load or close the loop with setWaterCooling to keep the heat in (0.5 ≈ half the dissipation).
The equilibrium is also moved by the fuel heat multiplier (diesel 1.25 → hotter), the engine length and the number of ducts.
Stress cost (draws on the engine's output)
Water cooling is not free: every working module permanently takes 512 SU of stress from the engine. It needs no shaft and no kinetic connection at all — attach it to a core (or to another water module) and it applies.
| Item | Rule |
|---|---|
| Draw | 512 SU per working module, constant — independent of throttle, speed, coolant amount and coolant efficiency |
| Configurable | Config key engineWaterCoolingStress (default 512, range 0~65536; 0 = water cooling is free). Changes apply when the world is loaded |
| Free when | the tank is empty (0 mB) / the loop is closed (setWaterCooling(0), pump stopped) / steam engine (where water cooling does nothing anyway) |
| No discount | Below 4000 mB the dissipation scales down but the stress cost does not: any coolant costs the full 512 SU |
| How it lands | The engine core registers itself as a stress-consuming member of the network, so the whole network really has that much less SU — this is not a display-only or fake deduction |
What it actually does:
- Attached machines really lose
512 SUof available capacity: share of the engine's total =512 / capacity. One fluid chamber (8192 SU) → 6.25%; two chambers (16384 SU) → 3.1%. - It can genuinely overload the network: once stress meets capacity the network goes overstressed (red text on goggles, machines stall). By design the engine keeps running and burning fuel — overload is a network state, not an engine state.
- ⚠️ Load rises with it: fuel burn and heat both follow the network load (
stress / capacity), so adding water cooling nudges both up. Net effect = more dissipation and a little more heat — the equilibrium tables above do not include this term, so real temperatures sit slightly higher than listed. Keep that margin in mind when sizing radiators.
Example: 1 fluid chamber (8192 SU) + 1 full water module, 4096 SU of machines attached
before: load = 4096 / 8192 = 50%
after: load = (4096 + 512) / 8192 = 56% <- fuel burn / heat follow 56%
Coolant consumption
Two consumptions exist side by side (computed server-side every tick, actually deducted only once 1 mB has accumulated):
| Consumption | Trigger | Rate |
|---|---|---|
| Running cost | Engine running (throttle ≠ 0 and not hard-stopped) | 1 mB per 8 seconds per working module (a full tank ≈ 17.8 hours) |
| Overheat boiling | Whenever T > 200°C (from the "about to overheat" band up, no running required) | 5.0 × (T − 200) × its own boilMultiplier mB/s per working module — 210°C ≈ 51 mB/s (a full tank ≈2.6 minutes) |
- Bookkeeping is per module: each module accumulates its own debt and is drained from its own tank — N modules means N tanks losing coolant at their own rates (never "only the first module drains").
- Boiling is proportional to temperature: the rate is 0 exactly at 200°C (no boundary flicker) and grows as it gets hotter.
- It keeps draining after the engine hard-stops: reaching 220°C hard-stops the engine (no fuel burned), but as long as the temperature stays above 200°C the coolant keeps evaporating — and less coolant → weaker cooling → hotter → faster loss (positive feedback). A full tank lasts ≈ 14 minutes at 219°C and ≈ 27 minutes at 210°C.
- Stopped engines pay no running cost: at throttle 0 only boiling drain applies (same semantics as "a stopped engine burns no fuel").
- With the loop closed (
setWaterCooling(0)) both consumptions stop (and the stress tie-up drops to 0) — but so does the cooling.
Steam engines
Water cooling has no effect on steam engines: it does not participate in their temperature (closed boiler self-regulation, see Steam Power Chamber), does not consume coolant and does not draw stress. Mounting one on a steam engine is purely decorative (the engine core's goggle shows "Coolant Cooling: none").
Comparison with the cooling air duct
| Water Cooling Module | Cooling Air Duct | |
|---|---|---|
| Dissipation per block (full effect) | 0.37 (≈ 4.1 ducts) | 0.09 |
| Ram-air (airspeed) bonus | small (25% of the ram bonus, ×1.25 at MAX) | yes (up to ×2 at 30 m/s, full) |
| Pressure (altitude) penalty | small (25% of the pressure loss, f 0.54 → ×0.885) | yes (pressure^0.8, full) |
| Running cost | coolant (1 mB / 8 s per module) + 512 SU stress per module | none |
| Overheat penalty | accelerated coolant evaporation | none |
| Fluid tank | 8000 mB (coolants only) | none |
| Adjustable | setWaterCooling loop opening |
setCooling shutter |
| Best for | static, low speed, high altitude | fast flight, no resupply |
Datapack: coolants
The coolant table lives in data/<namespace>/coolant/*.json, hot-reloaded with /reload:
| Field | Meaning |
|---|---|
fluid |
Coolant fluid id (the unique key). The table is the module's filling whitelist |
efficiency |
Cooling efficiency multiplier (default 1.0, must be > 0): multiplied directly into k_water |
boilMultiplier |
Boil-off multiplier (optional, default 1.0, must be > 0): higher = evaporates faster above 200°C |
- Bundled entries:
minecraft:water(1.0) andaeronautics:levitite_blend(1.5). Adding a coolant is just another json file — no code changes. - Fluid ids are decoupled from the installed mods: referencing a fluid from a mod you do not have will not crash; the log warns that the fluid is not registered and the entry is kept.
Goggle display
The module itself (goggles on it):
- Below 4000 mB the "Cooling" line appends "(low coolant, 4000 mB for full effect)".
- Empty tank / non-coolant → efficiency shows "no coolant", cooling shows "none".
Engine core (two extra places once a module is installed):
Engine Status
…
Load: 43%
Coolant Cooling: +0.37 ← none when out of coolant / loop closed / steam engine (grey)
Coolant Stress: -512 SU ← draws on the engine's output; 0 shows grey "none" (empty tank / loop closed / steam engine)
Connected Modules:
- Fluid Combustion Chamber x2
- Water Cooling Module x1
Why the module does not proxy to the core
Cooling ducts proxy their goggle to the engine core (engine temperature + shutter). The water cooling module deliberately does not: its coolant level and efficiency matter more than the engine temperature, so it keeps its own fluid tooltip. Hover the engine core to read the temperature.
Lua API
New methods (see Engine Lua API):
| Method | Description |
|---|---|
hasWaterCooling() |
Whether a water cooling module is installed |
getWaterCooling() / setWaterCooling(0~1) |
Water loop opening (default 1.0; 0 = closed loop: no cooling, no drain) |
getWaterCoolingPower() |
Current effective water dissipation k_water (amount ratio / efficiency / opening) |
getWaterCoolingModules() |
Number of working modules (amount > 0) |
getCoolantAmount() |
Total coolant in mB (sum over working modules) |
getWaterCoolingStress() |
Stress tie-up in SU (working modules × 512) — really applied to the network: attached machines lose that much capacity and it can cause a genuine overload |
local e = peripheral.find("ccpe:engine")
print(e.getWaterCoolingPower()) --> 0.37
print(e.getCoolantAmount()) --> 8000.0
print(e.getWaterCoolingStress()) --> 512.0
-- keep the heat in at low load: close half of the loop
e.setWaterCooling(0.5)
Related pages
- Engine System overview
- Temperature & Cooling Model — the full
K_totalformula plus the altitude/pressure curves - Cooling Air Duct — the air-side counterpart
- Engine Lua API